TR100 - T
TROUBLE SHOOTING
ERROR CODE MAIN REASON SOLUTION TO ERROR
E01 This error indicates a possible
message failure between
computer and bottom control
board.
1. Check that the computer and bottom
control board wires are connected
correctly.
2. Change the entire control board.
E02 This error indicates a possible
burnt bottom control board.
1. Check if the bottom control board is
burnt and replace it if it is damaged.
E05 This error indicates a possible
current overload.
1. If current overload has been detected
or the motor is stuck this will cause an
excessive current and the machine will
start self-protecting its system. Adjust
the machine and restart.
2. Check if the motor has a noise coming
from it or if the motor / bottom
control board has burnt out. If it has
burnt out, then change to a new
motor and/or bottom control board.
Use correct voltage moving forward.
E06 This error indicates that the motor
wire is possibly not connected
correctly.
1. Check the motor wires and ensure all
are connected correctly