29
3. After insert liner between the see through type gap sensor, press the 
button    under “V” icon to continue. 
4. Press the button    under “+” icon to increase Stock AD value by 
50 increment. And press the button    under “V” icon to calibrate 
the sensor sensitivity. 
 
 
 
 
 
4.1.2.1.2 Manual Gap: 
        If Auto Gap sensor calibration can not apply to the media, please use 
Manual Gap function to calibrate sensor manually. This function can be 
used to fine tune sensor sensitivity. When enter [Manual Gap] option, 
you will see following message. 
 
 
 
 
         Stock AD on liner   Stock AD on paper 
Press the    button under “+” and “-“ to increase and decrease 
sensor intension, and press the    under “V” to set the value to 
printer. 
When adjust the sensor sensitivity manually, we can get the different 
Stock AD on liner and paper in each sensor intension. The difference 
between these two values must be larger than 50 levels then printer 
can register label position correctly. 
 
GAP Calibrate 
185 
+     -     V 
Gap Sensor 
Stock AD = 50 
Intension = 140 
+     -      V 
Gap Sensor 
Stock AD = 163 
Intension = 140 
+     -      V