Dump mode
Printer will enter dump mode after printing printer configuration. In the dump mode, all
characters will be printed in 2 columns as following. The left side characters are received from
your system and right side data are the corresponding hexadecimal value of the characters. It
allows users or engineers to verify and debug the program.
Note:
1. Dump mode requires 4” wide paper width.
2. Turn off / on the power to resume printer for normal printing.
4.3.3 Printer Initialization
Printer initialization is used to clear DRAM and restore printer settings to defaults.
Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green after 5 amber blinks. (Any green will do during
the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green
ASCII Data
Hex decimal data related to left
column of ASCII data

Other manuals for TSC TE210 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TE210 Series and is the answer not in the manual?

TSC TE210 Series Specifications

General IconGeneral
Resolution203 DPI
Print Speed6 IPS
Print MethodThermal transfer / Direct thermal
Processor32-bit RISC CPU
InterfaceUSB 2.0, RS-232, Ethernet
Scan RateN/A (Barcode printer, not a barcode reader)
Barcode ResolutionN/A (Barcode printer, not a barcode reader)
Supported BarcodesCode 39, Code 128, UPC-A, UPC-E, EAN-13, EAN-8, Interleaved 2 of 5, Codabar, POSTNET
Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature-40 ~ 60°C (-40 ~ 140°F)
Humidity25 ~ 85% non-condensing (Operating)
Power Consumption100-240V AC, 50/60Hz