Appendix B
ACGIH Clothing Corrections
26
ACGIH Clothing Corrections
The following clothing corrections are in degrees Celsius. When a clothing correction is
entered into the setup portion of the QUESTemp 48N Heat Stress Monitor, the value is
added to the WBGT only for looking up the stay times. The WBGT value displayed by the unit
does not reflect corrections.
Clothing type
Clothing correction
(Addition to WBGT (ºC)
Work clothes (long sleeve shirt and pants)
Cloth (woven material) coveralls
Double-layer woven clothing
SMS polypropylene coveralls
0.5º
Polyolefin coveralls
Limited-use vapor-barrier coveralls
11º
Cited from American Conference of Governmental Industrial Hygienists, Threshold Limit
Values and Biological Exposure Indices for 2008. Reprinted with permission.
United States Navy
Physiological Heat Exposure Limits (PHEL) Time Table
(Without the presence of fuel combustion gases/fuel vapors)
The recommended working hours are shown based on a maximum of eight hours. Naval
personnel will follow a category, I - VI, based upon their function.
PHEL Curves (Total Exposure Time in Hours: Minutes)
WBGT(F)
I
II
III
IV
V
VI
80.0
>8:00
>8:00
>8:00
8:00
6:35
4:30
81.0
>8:00
>8:00
>8:00
8:00
6:35
4:30
82.0
>8:00
>8:00
8:00
7:05
5:25
3:40
83.0
>8:00
8:00
7:45
6:25
4:55
3:20
84.0
>8:00
8:00
7:05
5:55
4:30
3:05
85.0
8:00
7:45
6:30
5:20
4:05
2:50
86.0
8:00
7:05
5:55
4:55
3:45
2:35
87.0
7:25
6:30
5:25
4:30
3:25
2:20
88.0
6:45
5:55
4:55
4:05
3:10
2:10
89.0
6:10
5:25
4:30
3:45
2:50
2:00