Setting
RFID channels — overview of commands
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 124
See description of the output data, p. [}105].
Request
Loop counter See description of the output data
Command code 0x0010 (hex.), 16 (dec.)
Read/write head address See description of the output data
Length UID/EPC Not required
Start address
UHF inventory
0: Grouping of the EPCs inactive, continuous detection
1: Grouping of the EPCs active, continuous detection
>1: not defined
HF inventory
0: Grouping of the UIDs or USER data inactive,
edge-triggered detection
1: Grouping of the UIDs or USER data active,
edge-triggered detection
2: Not defined
3: Grouping of the UIDs or USER data active, continuous
detection (time-triggered via bypass time), tag in detection
range supported
> 3: Not defined
HF bus mode
0: Grouping of the UIDs or USER data inactive, continuous
detection (time-triggered via bypass time), tag in detection
range supported
1: Grouping of the UIDs or USER data active, continuous de-
tection (time-triggered via bypass time), tag in detection
range supported
>2: not defined
Length Not required
Timeout Not required
Write fragment No. 0
Read fragment No. See description of the output data
Write data Not required
See description of the input data, p. [}100].
Response
Loop counter See description of the input data
Response code 0x0010 (hex.), 16 (dec.)
Length 0
Error code See description of the input data
Tag in
detection range
See description of the input data
Data (bytes) available Increases during command execution
Tag counter Increases with each read or written UID/EPC
Write fragment No. 0
Read fragment No. See description of the input data
Read data See description of the input data