Setting
Testing and parameterizing RFID interfaces via the DTM
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 187
8.10.6 Example: Executing a read command with the DTM
In the following example, 8 bytes of a tag are read by a read/write head connected to channel 0
of the interface.
Right-click the device in the project tree.
Click Simulation.
Select RFID channel 0 in the central window.
Setting the length: Double-click current value.
Confirm all the subsequent messages.
a The DTM starts force mode. In force mode, all input values are written directly to the con-
nected device.
Enter the Length in bytes (example: 8).
Select the Command code from the drop-down menu (example: 0x0002 Read).
Fig.100: Executing a read command — window: Simulation
The read data is displayed in the Measured value window. The data format is hexadecimal.
Fig.101: Executing a read command — window: Measured value