Commissioning
Connecting the device to an EtherNet/IP scanner using RSLogix
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com
07.00 | 2022/09 | 68
Description Word offset Bit offset Bit length
Channel 0 Channel 1
Continuous Mode active 0x0003 0x004F 9 1
Loop counter 0x0002 0x004E 0 8
Antenna detuned 0x0003 0x004F 5 1
Parameter not supported by read/
write head
0x0003 0x004F 5 1
Read/write head reports error 0x0003 0x004F 6 1
Expected read/write head
not connected
0x0003 0x004F 7 1
Length 0x0004 0x0050 0 16
Error code 0x0005 0x0051 0 16
Tag counter 0x0006 0x0052 0 16
Data (bytes) available 0x0007 0x0053 0 16
Read fragment No. 0x0008 0x0054 0 8
Write fragment No. 0x0008 0x0055 8 8
Read/write head 1 —
Tag in detection range
0x000B 0x0057 0 1
… … … … 1
Read/write head 16 —
Tag in detection range
0x000B 0x0057 15 1
Read/write head 17 —
Tag in detection range
0x000C 0x0058 0 1
… … … … 1
Read/write head 32 —
Tag in detection range
0x000C 0x0058 15 1
Read data Byte 0 0x000D 0x0059 0 8
Read data Byte 1 0x000D 0x0059 8 8
Read data Byte 2 0x000E 0x005A 0 8
Read data Byte 3 0x000E 0x005A 8 8
… … … … 8
Read data Byte 14 0x0014 0x0060 0 8
Read data Byte 15 0x0014 0x0060 8 8
… … … … 8
Read data Byte 64 0x002D 0x0079 0 8
Read data Byte 65 0x002D 0x0079 8 8
… … … … 8
Read data Byte 126 0x004C 0x0098 0 8
Read data Byte 127 0x004C 0x0098 8 8