16
PowerSeries - PC1616/PC1808/PC1832/PC1864
Section [017] Fifth System Option Code
Section [018] Sixth System Option Code
Section [019] Seventh System Option Code
Section [020] Keypad Zone Assignment
Enter the two-digit zone number to be assigned to each keypad assigned to a specific slot. Only one keypad can be assigned to a specific slot. See Keypad
Assignment. Valid entries are from [00] to [64].
Option
Description
[1] ON: the system does not associate wireless keys to user codes. OFF: the system will assign user code 17 to wireless key #01, user code 18 to
wireless key #02 etc. If the wireless key is used to arm or disarm, the system will report the Opening/Closing for the associated User Code.
[2] ON: the system logs an RF Jam trouble condition if the condition is present for 5 minutes.
OFF: the system logs the trouble condition after 30 seconds.
[3] ON: the keypads beep if an RF Jam trouble is detected. OFF: the trouble is not annunciated via the keypad buzzer.
[4]
ON
: Double Hit feature Enabled. Two alarms from the same zone within the Cross Zone Timer Duration will cause the Police Code or Cross
Zone to be logged and transmitted.
NOTE: The Double Hit feature cannot be used on DD243 Listed systems.
OFF:
Double Hit feature Disabled.
Two alarms from the same zone will not cause the Police Code or Cross Zone to be logged and transmit-
ted. Two different zones must be in alarm to transmit the Police Code or verify the Cross Zone.This feature only applies to zones defined as
Interior, Instant Stay/Away, Interior Delay, Interior Stay/Away, or Delay Stay/Away (PIR Zones).
• This is a flexible extension of the existing Police Code.
• This feature is directly affected by the Cross Zone Timer.
[5] ON: the system logs and communicates a Late-To-Close event when it auto-arms at the programmed time (not if auto arming was caused
by the No-Activity Arming feature). OFF: the system does not transmit or log a Late-To-Close event.
[6] ON: enables the Daylight Savings automatic clock adjustment feature.
OFF: the system does not automatically adjust the clock for Daylight Savings.
[7] For Future Use
[8] ON: the system only squawks the bell output when the system is armed in the Away mode.
OFF: the system squawks the siren when the system is armed in any mode. (See Section [14]).
Option
Description
[1] ON: the system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during the
programmed time. OFF the system always transmits a Test Transmission reporting code as programmed.
[2] ON: Real-Time Bypass Reporting Enabled. When [][1] is used to bypass a non-24 hr zone, the system immediately logs and communi-
cates the zone bypass status.
OFF: Real-Time Bypass Reporting Disabled. When [][1] is used to bypass a non-24 hr zone, the system logs and communicates the zone
bypass status after the partition has been armed. Zone bypass statuses for 24-hr zones are still immediately logged and communicated.
[3]-[4] For Future Use
[5] ON: the keypad buzzer follows the bell output for all alarms. OFF: the system only activates the bell output for all alarms.
[6] ON: When an alarm is detected on a zone (with the Cross Zone attribute enabled), a timer is started. The alarm is not transmitted and the
bell output is not activated unless a second cross zone enabled zone is violated before the Cross Zone timer times out.
OFF: the system reports all alarms normally and logs and transmits a Police Code reporting code if a second zone alarm is detected during
the armed period.
[7] ON: the system restarts the Exit Delay (one time) if a Delay zone is violated and restored during the exit delay time.
OFF: exit delay does not restart.
[8] ON: the system activates the trouble beeps when an AC trouble is detected.
OFF: the system does not annunciate AC troubles using the keypad buzzer.
Option
Description
[1] For Future Use
[2] ON: Trouble light latches on.
OFF: Trouble light turns off after restore.
[3]
ON: When disarming, the keypad will display only the first alarm to occur during the last arming period
OFF: When disarming, the keypad will display all zones that were in alarm during the last arming period
[4]-[5] For Future Use
[6]
ON: the green LED indicator on the keypads indicate the status of AC on the system
OFF: the green LED indicator on the keypads indicate the partition ready status
[7] ON: All user access codes can enter the User Functions menu. OFF: Only the Master Code can enter the User Functions menu.
[8] For Future Use