Programming Descriptions
Section [021] Eighth System Option Code
Section [022] Ninth System Option Code
Section [023] Tenth System Option Code
Option
Description
[1] ON: Access codes will not be accepted by the system during entry delay. OFF: An access code can be used to disarm the system during
entry delay
[2] ON: EN Entry Procedure - The following zone type alarm will follow bell delay if a zone violation occurs while entry delay is active on
the partition: Instant, Interior, Interior Stay/Away, Delay Stay/Away, 24 Hr Supervisory, 24 Hr Buzzer, 24 Hr Burg, 24 Hr Holdup, 24 Hr
Gas, 24 Hr Heat, 24 Hr Medical, 24 Hr Panic, 24 Hr Emergency, 24 Hr Sprinkler, 24 Hr Water, 24 Hr Freeze, 24 Hr Latching Tamper,
Interior Delay, Day Zone, Instant Stay/Away, 24 Hr Bell/Buzzer, 24 Hr Non-Latching Tamper, Night Zone, Audible 24 Hr PGM Input. The
transmission delay attribute must be enabled for all burg type zones when this feature is ON. Transmission delay and bell delay times
should be programmed to be longer than entry delay. When entry delay ends, the bell delay will clear and the siren will activate. Any burg
type zone will follow transmission delay when the zone alarm occurred during the Entry Delay. When entry delay expires, the control
panel will delay the communication of the alarm for an additional 30 seconds to allow the user time to disarm before the signal is sent. The
police code or burglary verified timer will not begin until the additional 30 second transmission delay has expired without a valid disarming
procedure. If a zone violation occurs but entry delay is not active the bell will sound and the alarm will be communicated immediately
depending on the zone type tripped.
NOTE: The transmission delay attribute must be enabled for all burg type zones when this feature is on.
NOTE: Transmission delay and bell delay times should be programmed to be longer than entry delay.
OFF: Standard Entry Delay - If bell delay is activated, an alarm from a burglary type zone will follow bell delay regardless of entry delay
being active. If transmission delay is activated, the communication of an alarm from a zone with the tx delay attribute enabled will be
delayed regardless of entry delay being active.
[3]-[5] For Future Use
[6]
ON: Key-switches and wireless can only disarm the system during an entry delay. OFF: Key-switches and wireless keys can
disarm the system regardless if entry delay is active or not.
[7]-[8] For Future Use
Option
Description
[1]
ON: An access code is required for access to the [
][1], [][2], [][3] menus.
OFF: No access code is required for [
][1], [][2], [][3] menu access.
[2]-[3] For Future Use
[4] ON: Only the Master code can be used to bypass a hold up zone.
OFF: Any valid access code can bypass a hold up zone.
[5] For Future Use
[6] ON: RF Delinquency Enabled, if any wireless zone supervisory transmission is not received by the PC5132 during a 15-minute period, the
PC5132 will place the panel into Not Ready To Arm mode. In the armed state, the Zone faults will generate tamper alarms. The panel will
generate a silent trouble (NO trouble beeps but the Trouble LED is turned ON) called “RF Device Delinquency”, that’s only viewable in [*][2]
(Trouble Memory). The user can override the condition and arm the panel by using the feature.
OFF: RF Delinquency Disabled, the system will not indicate an RF Delinquency when a zone supervisory transmission is not received
during a 15 minute period.
[7] Future Use
[8] ON: When the system is armed in Stay mode, during the Exit delay, the system will sound 1 beep every 3 second.
OFF: When the system is armed in Stay mode, the system will be silent during the Exit delay.
Option
Description
[1] ON: the keypad [F] emergency key will only beep three times to acknowledge the button has been pressed. The system will not activate the
bell output. OFF: the system will activate the bell output and beep the keypad.
[2] ON: 200 Baud Open/Close Identifier Toggle 200 Baud Open Close Identifier is 2 for arming 1 for disarming.
OFF: 200 Baud Open/Close Identifier Toggle 200 Baud Open Close Identifier is 1 for arming 2 for disarming
[3] ON: the system will only transmit the Test Transmission reporting code if the system is armed at the time the system is programmed to
report the event. OFF: the system will always report the Test Transmission reporting code at the programmed time.
[4] ON: the system changes the Test Transmission Reporting Cycle Time from Days to Hours.
OFF: the Test Transmission Reporting Cycle Time is in Days.
[5] ON: the user cannot switch from Away Arm mode to Stay Arm mode using the function keys.
OFF: the user can switch arming modes.