23
Programming Descriptions
Section [402] Downloading Computer Phone Number
The Downloading Computer Telephone Number is used for Call Back, User Initiated DLS and the Auto Event Buffer Upload functions. Program the
phone number as required. HEX digits can be included for special applications:
Section [403] Downloading Access Code
Program the 6-digit Downloading Access Code. Upon connection, the system will only connect to the downloading computer if the
Downloading Access Code programmed matches the Downloading Access Code programmed in the computer file.
Section [404] Panel Identification Code
Program the 6-digit Panel Identification Code. This code is used by the downloading computer to verify the correct account is calling back (Call Back fea-
ture) or to identify which customer account file should be used (User Initiated DLS and Auto Event Buffer Upload features).
Section [405] Double-Call Timer
Program the maximum time, in seconds, between calls when connecting to panel using the double call feature. Valid entries are [000] to [255].
Section [406] Number of Rings to Answer On
Program the number of consecutive rings that panel must detect to answer for downloading. Valid entries are [000] to [010].
Section [499] PC-Link Communications
Enter the following command to initiate downloading via PC-Link – Section [499] [Installer Code] [499]. Plugging in the PC-Link connector will auto-
matically initiate the connection if DLS is initiated before connecting the PC-Link Header. The session will NOT be automatically initiated if the system
is in installer mode.
Section [501] to [514] Programmable Output Attributes
These Sections are used to customize the operation of the PGM outputs (Section [501] for PGM 1, Section [502] for PGM 2 etc.). The available options
depend on which PGM output type is programmed.
When the PGM Output Options (Section [009] to [011]) are programmed, the system will change the PGM Attributes to the default settings. The PGM
Attributes will default if a new PGM output option is programmed.
PGM Output Option [01], [03] to [08], [11] to [22], [25],[26], [28], [30], [33], [34]
PGM Output Option [19] to [22]
PGM Output Option [09]
[3] ON: the system will hang up after a successful DLS connection and call the computer back using the DLS Phone Number (Section [402]).
OFF: the system stays connected to the computer.
[4] ON: the user can initiate a downloading session using the [][6] command. OFF: the user cannot initiate a downloading session.
[5] ON: the system attempts to call the downloading computer after transmitting a Event Buffer 75% Full event to the central station.
OFF: the system does NOT call the downloading computer after transmitting this event.
[6] ON: Panel communicates with DLS at 300 Baud. OFF: Panel communicates with DLS at 110 Baud.
[7]-[8] For Future Use
HEX [A] Not used HEX [D] Additional dial tone search
HEX [B] Simulates a [] key press HEX [E] 2-second pause
HEX [C] Simulates a [#] key press HEX [F] End of phone number marker
Option
Description
[3] ON: the PGM output will operate normally (switch to ground when activated). OFF: the PGM output will be normally ground and switch
to open collector (open circuit) when activated.
Option
Description
[4] ON: the PGM output will activate for the duration of the PGM Output Timer when the [][7][x] command is performed.
OFF: the PGM output will latch until the [][7][x] command is performed again.
[5] ON: a valid user code must be entered after the [][7][x] command. OFF: user code is not required.
Option
Description
[1] ON: PGM output activates if a Service Required trouble condition is present.
[2] ON: PGM output activates if an AC trouble condition is present.
[3] ON: PGM output activates if a Telephone Line trouble condition is present.
[4] ON: PGM output activates if a Failure to Communicate trouble condition is present.
[5] ON: PGM output activates if a Zone Fault condition is present.
[6] ON: PGM output activates if a Zone Tamper condition is present.
[7] ON: PGM output will activates if a Wireless Low Battery trouble condition is present.
[8] ON: PGM output will activates if a Loss of Clock trouble condition is present.