46
[377] Communication Variables
Default
004 I_______I_______I_______I Swinger Shutdown (Alarms and Rest) 001-014 Transmissions
003
I_______I_______I_______I Swinger Shutdown (Tampers and Rest) 001-014 Transmissions, 000=disabled
003
I_______I_______I_______I Swinger Shutdown (Maint and Rest) 001-014 Transmissions, 000=disabled
000
I_______I_______I_______I Communication Delay 001-255 seconds
030
I_______I_______I_______I AC Failure Communication Delay 001-255 minutes, 000=disabled
040
I_______I_______I_______I TLM Trouble Delay No. of checks required - valid entries 003 - 255)
030
I_______I_______I_______I Test Transmission Cycle (land line) 001-255 days/minutes
030
I_______I_______I_______I For Future Use
007
I_______I_______I_______I Zone Low Battery Transmission Delay 000-255 days
030
I_______I_______I_______I Delinquency Transmission Cycle 000-255 days/hours
000
I_______I_______I_______I Communications Cancelled Window 000-255 minutes
Dependent on programming in section [702], option [3].
[378] Test Transmission Time of Day
Default
9999 I_______I_______I_______I_______I Valid entries are 0000-2359 (9999 to disable)
[379] Periodic DLS Time of Day
Default
9999 I_______I_______I_______I_______I Valid entries are 0000-2359 (FFFF to disable)
[380] First Communicator Options
[381] Second Communicator Options
Opt Def ON OFF
1
Communications Enabled
Communications Disabled
2
Restorals on Bell Time-out
Restorals Follow Zones
3
Pulse Dialing
DTMF Dialing
4
Switch to Pulse Dialing on 5th Attempt
DTMF Dial For All Attempts
5
3rd Telephone Number Enabled
3rd Telephone Number Disabled
6
Alternate Dial (1st & 3rd)
Call 1st Number, Back up to 3rd
7
For Future Use
8
Delinquency Follows Zone Activity (Hours)
Delinquency Follows Arming (Days)
Opt Def ON OFF
1
Open After Alarm Keypad Ringback Enabled
Open After Alarm Keypad Ringback Disabled
2
Open After Alarm Bell Ringback Enabled
Open After Alarm Bell Ringback Disabled
3
SIA Sends Programmed Reporting Codes
SIA Sends Automatic Reporting Codes
4
Closing Confirmation Enabled
Closing Confirmation Disabled
5
Talk/Listen on Phone Lines 1/3
No Talk/Listen on Phone Lines 1/3
6
Talk/Listen on Phone Line 2
No Talk/Listen on Phone Line 2
7
Contact ID Uses Programmed Reporting Codes
Contact ID Uses Automatic Reporting Codes
8
Future Use