47
[382] Third Communicator Options
* A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
[389] TL/GS Fault Check Timer
Default: 003 |_____|_____|_____| Enter number of checks x 3 seconds. Valid entries are 002-255.
DLS Downloading
[401] Downloading Option Codes
[402] DLS Downloading Telephone Number (32 Digits)
|___
D
__|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|__ _____|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| _______|
[403]-[404] DLS Downloading Access Code / Panel ID Code (Enter 6 Hexadecimal Digits)
[405] Answering Machine Double Call Timer [406] Number of Rings to Answer On
Default 060 I_______I_______I_______I (001-255 seconds) Default 000 I_______I_______I_______I (000-255 rings)
[499] Initiate PC-Link Downloading
Enter [499][Installer Code][499]
Opt Def ON OFF
1
Contact ID Partial Closing Identifier is “5”
Contact ID Partial Closing Identifier is “4”
2
Alarm Communications Enabled During Walk Test
Alarm Communications Disabled During Walk Test
3
Communication Cancelled Message Enabled
Communication Cancelled Message Disabled
4
Call Waiting Cancel Enabled*
Call Waiting Cancel Disabled
5
TL/GS Interface Enabled
TL/GS Interface Disabled
6
AC Failure Transmission Delay is in Hours
AC Failure Transmission Delay is in Minutes
7
Number of Dialing Attempt for Residential Dial is 1
Residential Dial Follows Dialing Attempts Counter
8
For Future Use
Opt Def ON OFF
1
Answering Machine/Double Call enabled
Answering Machine/Double Call disable
2
User Can Enable DLS Window
User Cannot Enable DLS Window
3
Call Back Enabled
Call Back Disabled
4
User Initiated Call Up Enabled
User Initiated Call Up Disabled
5
Auto Event Buffer Upload Enabled
Auto Event Buffer Upload Disabled
6
300 Baud Call Up
110 Baud Call Up
7
For Future Use
8
For Future Use
Panel Default [403] Downloading Access Code [404] Panel ID Code
PC1616 161600
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|
PC1808 180800
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|
PC1832 183200
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|
PC1864 186400
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|