5 - 11
MAINTENANCE AND SERVICE
43
5
(3) Fuel filter cleaning and
element replacing
This filter is to remove foreign mate-
rial and water from fuel.
Set the fuel lter cock to the 'OFF'
position.
Loosen the ring screw on top of
the cap to remove the cap. Then,
Flush the element with diesel fuel
to remove any foreign material
from it.
If the element is severely contami-
nated, replace it with a new one.
Replace the fuel filter every
500hrs ofter replacing it at first
50hrs.
NOTE
7. CHECKING AND CLEANING AIR CLEANER
Check and clean the air cleaner ac-
cording to the following instructions:
< Cautions for inspection and
service of air cleaner >
(1) Use the standard element and l-
ter and do not apply oil on them.
(2) Remove any dust in the cover
thoroughly.
(3) Install it firmly so that dust does
not enter below the cover.
(4) Never drive with the element and
lter removed.
T4NO507A
Air cleaner body
Element
VACUUM VALVE CLEANING
Pull out the valve with a hand and
remove dust from its inside. If it
is dirty or watery, wipe it with a
dry rag thoroughly before tting it
again.
T474NCUSM1-영문-05(마).indd 11 2019-02-21 오전 8:43:30