6 - 14
CABIN SYSTEM
DIAGNOSING MALFUNCTIONS
1. TRACING
FAULTS
SYMPTOM CONDITION CAUSE REMEDY
1.Compressor Abnormal sound Inlet sound
Outlet sound
Insufcient Lub
Replenish
Belt tension release
Adjust
Release the bracket
Tighten the bolts
Clutch fail
Check
Abnormal revolution Inlet cause
Damaged parts
Check, Replace
Slip the clutch
Check, Replace
Not Lub
Replenish
Outlet cause
Belt tension released
Adjust
Refrigerant or oil
leakage
Refrigerant or oil leakag
Sealing washer damaged
Replace
Head bolt released
Tighten the bolts
D-ring damaged
Replace
Excessive pressure Low, High pressur
Insufcient refrigerator
Adjust
Compressor
Replace
2.Motor Weak from pres-
sure or don”t work
Motor is normal
Air inlet clogged
Remove
Evaporator freezing
Controlling minimum pressure
Ventilator switch damage
Replace the switch
Compressor
Replace
Motor is abnorma
Motor failure
Replace
Wire cut
Replace
Air leakage
Duct leakage
Check, Tighten
Unable to control
the fan
Motor
Air volume control switch failure
Check, Tighten
Motor is abnormal
Motor failure
Replace
T474NH-영문-06(바).indd 14 2019-03-06 오전 10:01:18