EasyManua.ls Logo

TYM T474 - 11. Checking Electric System; Checking and Charging Battery

TYM T474
175 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 16
MAINTENANCE AND SERVICE
11. CHECKING ELECTRIC SYSTEM
When charging the battery af-
ter removing it from the tractor,
it produces hydrogen gas, pre-
senting a fire risk. Charge the
battery only in a well-ventilated
area.
The battery produces highly
f l a m m a b l e h y d r o g e n g a s
which can explode. Keep flam-
mable items and spark away
from the battery.
The battery electrolyte is sulfu-
ric acid so can burn your skin
and eyes. Be careful not to
spill any.
DANGER
CHECKING AND CHARGING
BATTERY
If the battery electrolyte gets
on your eyes, skin, clothes
or object, rinse it with water
thoroughly. If you swallowed it,
drink a lot of water. Also, get
medical attention immediately
if acid contacts your eye or is
swallowed.
DANGER
The battery has the charge indicator:
check Battery Status
Green Fully charged
Red Charging required
White Insufficient electrolyte
T253O521A
Charge indicator
T474NH-영문-05(마).indd 16 2019-08-16 오전 11:30:42