DESCRIPTION OF TRACTOR CONTROLS
2 - 16
4. INSTRUMENT PANEL LAMP AND BUZZER OPERATING CONDITIONS
Item Lamp Buzzer
DPF regeneration
necessary
ON
Buzzing 3times [1s-1s-1s],
buzzing again in 1minute
DPF regeneration
start
Buzzing 1time [2s]
During DPF
regeneration
[DPF]+[EGT] on + Regeneration
button blinking
DPF regeneration
complete
Lamp Off Buzzing 3
times [1s-1s-1s]
INSTALLATION AND DPF REGENERATION
1) Cleaning logic (30% valve operation) is performed at every key-On after electronic exhaust valve leaning.