Ultimaker 2+ Connect user manual 30
5.4 Replace the Air Manager lter
The lter in the Air Manager is a consumable. It should be replaced every 1,500 printing hours to
maintain proper ltering.
Do not change the lter of the Air Manager while the fan is in operation. Turn o the printer to make sure the
fan cannot start unexpectedly.
The function of the Air Managers lter is to reduce the emission of ultrane particles. These particles will
remain in the lter. The used lter should be handled with care during the replacement procedure. If the used
lter is not properly handled, there is a risk of the ultrane particles being released.
1. Remove the Air Manager cover
2. Take out the used lter by pulling the tab on the lter towards you and removing it from the lter housing
3. Directly place the used lter in a (resealable) bag and close it
4. Insert the replacement lter into the lter housing and gently push it. Ensure the lter is completely ush
5. Place the Air Manager cover onto the printer and turn on the Ultimaker 2+ Connect
The lter in the sealed bag can be disposed of with your regular household waste.