DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R]
7
2-4. DC power supply unit (DPG-30R) specifications
Table 2-1 Electrical specifications (single unit specifications)
Input voltage fluctuation range
41.5 kVA or lower, 400 VAC 37 kVA
*change according to customer usage.
85.0% or higher
*1
, 87.3% when 400 VAC
0.88
*1,2
, 0.91 when 400 VAC
55 A
max
*restricted to 50A
max
, When abnormal discharge prevention unit use.
*6
1200 V
max
*4
*restricted to 800V
max
When abnormal discharge prevention unit use.
*6
1200V
5A 55A
200V
25A
545.5V
30kW
V2
V3
V4
I3I2
I1
V1
1300V
Abnormal discharge control
When abnormal discharge is detected, the inverter stops and output is
shut off by the low arc energy circuit
Constant power control (P control)/constant current control (I control)
*5
/
constant voltage control (V control)
*3
Rated output ± 0.5% or lower, or setting ± 1%, whichever is larger (at 9.6
Ω resistive load)
Constant power control, 10 to 100% of rated power value
*1 With 380 to 480 VAC input voltage
*2 May change depending on input-side equipment.
*3 V control is enabled only when using a single power supply.
*4 1300V
max
when ignition
*5 Abnormal discharge prevention unit in use can not be used
*6 Turn OFF the switch of LARC DC power back abnormal discharge prevention unit when using
Table 2-2 Other specifications
Within 481 mm (W) x 1000 mm (D) x 222 mm (H) * Not including protrusions
Indoors, 1000 m or lower altitude, out of direct sunlight, no corrosive gases
During operation: 35% to 85%; During storage: 25% to 85%; Both no condensation
Obtained standard certifications
CE (EN61000-6-2, EN61000-6-4, EN61010-1, EN60204-2)*
SEMI F47, RoHS support (EU)