DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R]
23
・3-2-3. Arc link terminal pin assignments
On the reference to "Table 2-7 external control signal equivalent circuit connection" to use the
ARC LINK terminal, Connected to an external control device such as a PLC
Table.3-4 Arc link terminal pin assignments
Apply 24 V from outside. 100mA or more
High speed pulse Low level output between 32us during hard arc detection
on the DC unit
Fast hard arc signal common return.
High speed pulse Low level output between 32us during micro arc detection
on the DC unit
Fast micro arc signal common return.
*1 Please do not connect 7,8,10,11 pin because it becomes the antenna to pick up noise and you have to
open the long-distance wiring.