EasyManua.ls Logo

UniCarriers FD160-2 - Page 139

UniCarriers FD160-2
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PERIODIC INSPECTION
4-40
BRAKE SYSTEM
Checking
item
Service Required Tools Daily
Monthly
(200 hrs)
Trimonthly
(600 hrs)
Semiannually
(1200 hrs)
Annually
(2400 hrs)
Booster
Check air cleaner for cleanliness. Cleaning
Check for proper function. Operate
Check relay valve and check valve air gap. Touch
Check hydraulic piston check valve for operation.
Oil pressure
gauge
Check booster for operation. Operate
Disassemble and clean booster (air master). Disassemble
Drain air tank. Operate
Check and change air drier compressed air desiccant. Disassemble
Replace rubber parts (“O”-ring and seals). Disassemble
LOAD HANDLING SYSTEM
Checking
item
Service Required Tools Daily
Monthly
(200 hrs)
Trimonthly
(600 hrs)
Semiannually
(1200 hrs)
Annually
(2400 hrs)
Forks
Check for damage, deformation or wear. Visual
Check for roots and teeth welded area for cracks or wear. Visual
Mast, forks
and lift bracket
Check for installation and deformation. Visual
Check welded area of outer and inner mast cross members
for cracks or damage.
Visual
Check welded area between tilt cylinder bracket and mast
for cracks or damage.
Visual
Check welded area of outer and inner masts for cracks or
damage.
Visual
Check welded area of lift bracket for cracks or damage. Visual

Table of Contents

Related product manuals