Commissioning
PG-E-Series | Version 2.15 15
8.1 Before starting
Step 1: Check that no power consumer is connected to
the generator.
Step 2: Check grounding. Proper grounding of the gene-
rator will prevent electric shock in the generator
or connected electrical equipment. Proper
grounding also prevents static electricity, which
often builds up in ungrounded equipment.
Step 3: Check the air filter: make sure it is in good condi-
tion and free of dust or dirt. Refer to the motor
manual for access to the filter.
Step 4: Put the battery into operation.
Step 5: Check motor oil level, top up if necessary. Select
the suitable motor oil depending on the tempera-
ture.
Fig. 13: Viscosity grade of the oil according to the temperature
Place the generator on a flat surface.
Clean the area around the filling opening. Re-
move the cap, pull out the dipstick and wipe it off.
Slowly pour the oil through the oil filter into the
motor until the level reaches the mark on the dip-
stick. In the meantime, check the level several
times. Never exceed the maximum filling level!
Close the filling opening tightly with the cap.
Check the oil level before each motor start!
Step 6: Fill the tank with petrol. Use always unleaded re-
gular petrol. Never use petrol containing more
than 10% ethanol. Leave about 4 cm free space
in the tank for the gasoline expansion (Fig. 14).
Fig. 14: Gasoline expansion
Close tightly the filler hole with the cap. Wipe up the spil-
led petrol!
Fig. 15: Petrol fill level
CAUTION!
Never fill tank indoors.
Never fill fuel tank when the motor is running or hot.
Do not overfill the tank (do not fill to the top of the fil-
ling device), fuel may leak due to motor vibrations.
Take care that no petrol drips to the ground during
refuelling.
Make sure that the fuel filler cap has been closed
correctly after refilling. If petrol has dripped on the
floor, make sure that the environment is dry before
starting the motor.
Avoid direct physical contact with the fuel and do not
inhale vapours; keep out of the reach of children.
The petrol vapours are flammable. Never light ciga-
rettes or smoke when refuelling. Avoid open fires.
CAUTION!
Do not come into contact with the acid and do not
smoke or use open fire: the vapours emitted by the
battery are highly flammable! Keep the battery acid
out of the reach of children.
ATTENTION!
Never fill the tank while the motoris running! The
generator must cool down for at least 2 minutes
before opening the filler cap.
Slowly open the fuel filler cap to equalize the pres-
sure.
Never mix oil with petrol!
Never overfill the fuel tank. Leave room for the petrol
to expand.
Regularly check the lines, tank and cap for leaks or
damage. Replace if necessary.
If the generator is operated at an altitude of more
than 1500 m above sea level, petrol with at least 85
octane must be used.
Tank
Petrol
Fuel gauge
full
empty
Fuel gauge
Tank cap
Max. fill level (red)
Max fill level (red)