Notes on the proper storage of the power generators
PG-E-Series | Version 2.15 19
9.3 Maintenance plan
10 Notes on the proper storage of the
power generators
Storage shorter than 30 days:
- Start the generator every 7 days and allow it to
warm up - however, storage should generally be
avoided
- Storage must be guaranteed in a dry and dust-free
room
- Do not expose to large temperature fluctuations (
The temperature range should be between mini-
mum 0° Celsius and maximum +40° Celsius)
shorter than 1 year:
- Clean and cover the generator.
- Before storing, change the oil, as it is possible that
old oil will have drawn water and components in
the generator will begin to corrode.
- (Change the engine oil when the engine is warm
and not hot).
- Fill up with high-quality fuel, preferably without et-
hanol and with suitable additives (stabilisers, antio-
xidants, corrosion protection).
- Disconnect the battery and connect it to a voltage
maintenance device (battery should be stored in a
room at approx. 20° Celsius).
longer 1 year
Note: It is important to remove all liquids from the gene-
rator, as fuel such as petrol and diesel in particular only
have a shelf life of approx. one year.
- Remove all liquids (oil and fuel) from the generator.
It is also important to ensure that the carburettor is
free of fuel.
- Remove the spark plug and cover the openings
with a clean cloth.
- Pour 15 ml of engine oil into the cylinder and crank
the generator a few revolutions so that the oil is
distributed.
- Screw the spark plugs back in
- Preserve the oil and petrol or diesel tank with
suitable corrosion protection.
- Disconnect the battery and connect it to a voltage
maintenance device (at best, the battery should be
stored in a room with a temperature of approx. 20°
Celsius).
- Ensure storage in a dry and dust-free room
- Do not expose to large temperature fluctuations
(the temperature range should be between a mini-
mum of 0° Celsius and a maximum of +40° Cel-
sius).
Commissioning
- Change or fill engine oil
- Change oil, air and fuel filters
- Unscrew and clean spark plug, check distances if
necessary.
- Let the generator crank a little without the spark
plug by pulling the cable so that the oil is distribu-
ted.
- Install spark plug
- Fill with suitable fuel
Important note
When the generator is started, smoke will initially be pro-
duced. The reason for this is that the oil that was pre-
viously filled in also burns.
When stored for a longer period of time, the rotor in the
synchronous motor loses its residual magnetism and can
no longer generate voltage. To prevent this, it is recom-
mended that the generator is subjected to a test run of at
least 15 minutes at least once a month. In case of pro-
blems, contact Stürmer Service.
Maintenance inter-
val or operating
hours
Maintenance point
after the first 5
hours
Change engine oil
8 hours or daily Check oil level.
Clean from deposits.
25 hours or annually Clean air filter
50 hours or annually Change engine oil
yearly Change air filter
Service valve clearance
Service spark plug, change if
necessary
Check silencer and spark ar-
rester
Clean cooling system