EasyManua.ls Logo

Unitech K2724 - Page 32

Unitech K2724
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page B.5
B.5 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128
Enter Group 5 Group Default
0
1
2
3
4
5
6
7
8
9
Code 39: 0/1--Disable/Enable.
2/3--Full ASCII/ Standard.
4--Check Digit (CD) Calculate & Send.
5--CD Calculate, not send. 6 --CD not Calculate.
7/8 -- Send/No Send Start/Stop
9/: -- Double labels decoding Off/On
0 - 48 -- Min length 0 / Max length 48
F
1
I 2 of 5 (ITF): 0/1--Disable/Enable
2/3--Fix Length On/Off ( by first three reads)
4--Check Digit (CD) Calculate & Send
5--CD Calculate, not send. 6--CD not Calculate
7--First Digit Suppressed. 8--Last Digit Suppressed
9 -- Not Suppressed
2 - 64 -- Min length 10 / Max length 64
F
2
S 2 of 5 / China Postal Code(Toshiba Code):
0/1--Disable/Enable
2/3 -- Fix Length On/Off ( by first three reads)
4--Check Digit (CD) Calculate & Send
5--CD Calculate, not send. 6--CD not Calculate
1 - 48 -- Min length 4 / Max length 48
F
3
Code 32(Italian pharmacy):
0/1 -- Disable/Enable
2/3 -- Leading Character Send / No Send
4/5 -- Tailing Character Send / No Send
F
4
Telepen:
0/1 Disable/Enable 2/3 Standard/Numeric Set
F
5
UCC/EAN 128: 0/1disable/Enable
2/3Code ID disable/Enable
Note: If EAN128 be disabled, the EAN128 labels will
be decoded as Code 128
F 6
Define the EAN128 Fields separator:
Scan a ASCII code in full ASCII code chart to select
a new Fields Separator
F 7
Define a separator for double labels:
Scan a ASCII code in full ASCII code chart to select a
new definition of Func1
F8
Min Length Max Length
MM
N
N
Exit

Other manuals for Unitech K2724