EasyManuals Logo

Unitech MS920 User Manual

Unitech MS920
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
125
Double scan prevention
- When enabled pulling the trigger a second time does not start a new reading
session unless the timeout has expired. This prevents the user from
accidentally scanning the same bar code twice.
- Use the "Timeout between identical consecutive codes" located in "Data
decoding security" to set the timeout.
- Note: The default value of the timeout is not suitable for double scan
prevention. Be sure to adjust it if using this feature.
Scanning / Triggering - Double scan prevention - Disable (*)
<SW>705000
Scanning / Triggering - Double scan prevention - Enable
<SW>705001
Data decoding security
- Ensures correct transmission of data for difficult reading conditions and
varying levels of barcode quality (poorly printed labels, variable lengths and no
check digit, "fragile" symbologies).
- Increasing the security level reduces the reading speed !!!
Predefined security levels
- Predefined security level settings can be modified individually
- Use medium and high security levels for poor-quality bar codes or critical
applications.
- Increasing the security level reduces the reading speed!!!
- Auto read count before transmission.
- 300 ms between identical consecutive codes.
- No timeout between different consecutive codes.

Table of Contents

Other manuals for Unitech MS920

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unitech MS920 and is the answer not in the manual?

Unitech MS920 Specifications

General IconGeneral
BrandUnitech
ModelMS920
CategoryScanner
LanguageEnglish

Related product manuals