REF.
DESCRIP-
TION
SUPPLIER I V F P Q S PF
L
@
R
@
Z
@
DCR X/R
θ
A Contactor
VE1095A0 /
GE– CL01A400T
30
mA
230 V ~ 50 Hz 2 W 6 Var 6.5 Va 0.31 13 H
2 k 9.4 k770
4.42
77.2°
B
Solenoid
valve
VE1135A0 /
RPE – SERIE R
30
mA
230 V ~ 50 Hz 4.7 W 4.5 Var 6.5 Va
0.72
9 H
4.7 k7.4 k4.3 k
1.19 50°
C Pump
VL1038A0 /
A.R.S. – MPP1
185
mA
140 V ~ 50 Hz 21 W 30 Var 36 Va
0.58
1.75 H 660 1 .3 k
580
1.66 59°
E Fan
VN1162A0 /
SUNON –
DP200A
130
mA
230 V ~ 50 Hz 21 W 19 Var 28 Va
0.75
3.4 H
1.1 k 1.6 k 626
1.11 48.1°
F Motor
MT1012A0 /
SISME
1.62 240V 60 Hz 388W 30.5
G
DRY.Maxi
solenoid
VE1135-VE1140-
VE1014
RPE SERIES R
230V 50 Hz 8VA
LEGEND
I Load current consumption
V Voltage applied to the load
F Frequency
P Load active power
Q Load reactive power
S Load apparent power
PF Power Factor (PF=P/S)
@ 100Hz measured inductance
@ 100Hz measured resistance
@ 100Hz measured impedance
DCR Measured resistance in DC
X/R Q=|X/R| (X=reactance, R=resistence)
θ
angle between real axis and the impedance vector