P20
INARLOCK 4P
1F
(Black)
1 TL3 Output phase # 3
2 N
Neutral output contactor # 3
3 N
Neutral output contactor # 4
4 TL4 Output phase # 4
P5, P6
1
-
+13V
Bridge connection (CANBUS)
2 B
3 A
4 GND
P18
1
Multi-
point
HEART_4
Multipoint core probe input
2 -
3 GND
4 HEART_1
5 HEART_2
6 HEART_3
P8 MINIFIT 4P
1
Di1
IN
Auxiliary input #1
2 GND
3
DI2
IN
Auxiliary input #2
4 GND
P9
AMP Modu II
4P
1
TAC1/2
+13V
Tachometer input TAC1 and
TAC2
2 IN_TAC1
3 IN_TAC2
4 GND
P12
INARLOCK 5P
1F
(Black)
1 N
Motors’ neutral input from PE2038
2 RW
Input RW (reverse) motors from PE2038
3 FW
Input FW (forward) motors from PE2038
4 F Motors’ input phase from PE2038
5 TM
Output thermal protection towards PE2038
P11
INARLOCK 5P
1F
(White)
1 N
Motors’ neutral output group # 1
2 RW
Output RW (reverse) motors’ group # 1
3 FW
Output FW (forward) motors’ group # 1
4 F Output TSA motors’ group # 1
5 TM Input TSR motors’ group # 1
Environmental parameters
PARAMETER MINIMUM VALUE MAXIMUM VALUE
WORKING TEMPERATURE +10 °C (50F) +70 °C (158F)
STORAGE TEMPERATURE -10 °C (14F) +70 °C (158F)
ENVIRONMENTAL WORKING
HUMIDITY
- 80%
STORAGE HUMIDITY - 90%
MOLEX Microfit
4P
MOLEX Microfit
6P 2F