Outputs
NAME
LOAD
DESCRIPTION
ACTUALIZA-
TION
VOLTAGE
CURRENT
TYPE OF
LOAD
TL Contactors RL4
240 Vrms
120 mA A •
EV
Steam solenoid valve
RL3
240 Vrms
60 mA
B
•
FAN
Cooling fan
RL2
240 Vrms
260 mA E •
RES
Braking element
number 1
RL7
240 Vrms
- -
•
MOT2 Motor direction RL6
240Vrms
8A
F
•
MOT1
Motor triac control (ON/
OFF)
Triac 240 Vrms 8 A
F
•
BUZZ
Motor triac control (ON/
OFF)
Mosfet 12Vcc
G
•
LATCH
Motor triac control (ON/
OFF)
Mosfet 12Vcc
-
•
REF.
DESCRIP-
TION
I V F P Q S PF
L
@
R
@
Z
@
DCR X/R
θ
A Contactors 30 mA 230 V 50 Hz 2 W 6 Var 6.5 Va 0.31 13 H
2 k 9.4 k 770
4.42
77.2°
B
Steam
valve
30 mA 230 V 50 Hz 4.7 W 4.5 Var 6.5 Va
0.72
9 H
4.7 k 7.4 k 4.3 k
1.19 50°
E
Cooling
fan
230 V 50 Hz 21 W 19 Var 28 Va
0.75
3.4 H
1.1 k 1.6 k 626
1.11 48.1°
F Motor 1.62 A 240V 60 Hz 388W -
-
30.5
G
External
buzzer 12V
10 mA 12Vcc cc 50 Hz
LEGEND
I Load current consumption
V Voltage applied to the load
F Frequency
P Load active power
Q Load reactive power
S Load apparent power
PF Power Factor (PF=P/S)
@ 100Hz measured inductance
@ 100Hz measured resistance
@ 100Hz measured impedance
DCR Measured resistance in DC
X/R Q=|X/R| (X=reactance, R=resistance)
θ
Angle between real axis and the impedance vector