ENGLISH
20
9
.End programming
To exit the programming and store the settings of the different parameters, it is necessary to follow this procedure:
PLEASE NOTE: To select the button to be used to control the automation system, please refer to section “5. Selecting the
remote control button”
DELETING REMOTE CONTROL UNITS
P
ress the + key until the
display shows
II
Press and hold the key
for 5 seconds:
II
flashes
Release the key: the
s
egments of the display
illuminate one at a time
until showing
00
MEMORISING REMOTE CONTROL UNITS
The device can memorise up to 15 remote control units. To memorise a remote control unit, proceed as follows:
Press the key
The dot appears on the
display after approx.
1 second
Release the key and press the remote control button
twice: the device emits a BEEP and the dot is turned off
to confirm memorising has been successful
Press and hold key
The dot appears on the
display after approx. 1
second
Hold the key until the display is turned off : the remote
controls have been deleted.
Display Reason
L
The display shows the letter L when the actuator is working normally and the red cam positioned on the chain activates
the micro switch on the motor
F The display shows the letter F when the door encounters an obstacle
H The display shows the letter H when the encoder or the control unit is malfunctioning
A The display shows the letter A when the photocell intervenes
DISPLAY MESSAGES