EasyManuals Logo

V2 ZORUS User Manual

V2 ZORUS
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
ENGLISH
- 53 -
8.1 - POWER ADJUSTMENT
This rapid configuration menu option allows the motor power to
be adjusted. The value displayed is the value currently set. Using
the h and i keys, select the value to be set and press OK to
confirm and continue.
30 ÷ 100 Values from 30 (minimum) to 100 (maximum).
Equal values for both motors
PErS Customised configuration: if the display shows
PErS, this means the two motors have different
power values set using the Pot1 and Pot2
options in the control unit programming menu.
Selecting the PErS options exits the menu,
maintaining the previously set values.
8.2 - OBSTACLE SENSOR ADJUSTMENT
The PD12 control unit has a sophisticated system allowing
detection of whether gate movement is impeded by an obstacle.
This system is based on measurement of the current absorbed by
the motor: an unexpected increase in current absorption indicates
the presence of an obstacle. the obstacle sensor is also used to
recognise the arrest points.
Detection of an obstacle during normal movement of the gate
results in brief inversion of motion in order to free the obstacle.
The gate is stopped when one of the following conditions is
present:
- During slowing
- During the first work cycle after accessing the programming
menu
- After having powered-up the control unit
This menu option is used to adjust the motor current value that
trips the obstacle sensor.
The value displayed is the value currently set. Using the h and
i keys, select the value to be set and press OK to confirm and
continue.
The possible options are:
1.0 ÷ 3.5 Values from 1.0 to 3.5 Amperes: values common to
both motors. The minimum value corresponds to
maximum obstacle sensor sensitivity, and vice-versa.
Based on the value selected, the control unit also
calculates the acceleration and deceleration rate and
the start thrust function.
PErS Customised configuration: if the display shows
PErS, this means the two motors have different
values set using the SEn1 and SEn2 options in
the control unit programming menu.
Selecting the PErS options exits the menu,
maintaining the previously set values.
Please note: if time self-training has been performed during
initialisation, the control unit has also performed automatic
strain recognition and has automatically set the sensitivity
value.
If, on the other hand, self-training has not been performed,
the pre-set value is the default.
30
100
60
PErS
Pot.
1.0A
3.5A
3.0A
PErS
SEnS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the V2 ZORUS and is the answer not in the manual?

V2 ZORUS Specifications

General IconGeneral
BrandV2
ModelZORUS
CategoryGate Opener
LanguageEnglish

Related product manuals