CONFIGURATION/PARAMETERIZATION 66
Parameter: MC 8/10M (IR remote control)
WARNING!
Danger due to switched off limit switches
Accidents, severe injuries as well as property damages
No limit switches are active in the infrared manual mode (except if it was set in
advance)!
The IR manual mode will be deactivated by actuating the ON/OFF switch on the
control system.
Parameter Selection Description
MC 8/10M (IR remote
control)
Check box Activate if a remote control is used.
Manual mode activa-
tion mode
Via M/A button The control system will be switched into manual mode using
the button [MAN].
Via M/A button +
CODE
The control system will be switched into manual mode using
the button [MAN] and subsequent code input (vehicle num-
ber).
Save manual mode
zero voltage proof
Active Behavior if voltage returns:
Active: Control system remains in IR manual mode
Inactive: Control system switches into automatic mode
Inactive