Gas installation
ecoTEC plus installation and maintenance instructions 0020134823_01 17
5
5 Gas installation
The work described in this section must only be carried out
by a competent person.
5.1 Preparing for installation
a
Danger!
Risk of death caused by improper gas
installation!
An incorrect gas installation may result in
leaks and an explosion.
> During installation, the legal directives
and the local regulations for gas supply
companies must be observed.
a
Danger!
Risk of death caused by improper gas
installation!
Tension in the gas line may result in leaks
or an explosion.
> Make sure there are no stresses in the
gas lines when it is installed.
b
Caution.
Risk of material damage caused by incor-
rect gas installation.
Excess test pressure may cause damage to
the gas valve.
> When checking the gas valve for leak-
tightness, use a max. test pressure of
1.1kPa (110mbar).
> During the gas installation, ensure that
the home pressure regulation for the
required gas flow pressure of 5mbar is
maintained in accordance with the tech-
nical data (
¬section18).
b
Caution.
Risk of material damage caused by con-
taminated lines.
Foreign bodies, such as welding remnants,
sealing residue or dirt in the supply lines
for gas, may cause damage to the boiler.
> Blow the gas line thoroughly clean prior
to installation.
b
Caution.
Risk of material damage caused by the
incorrect gas type.
Using the wrong gas type may cause a fault
shutdown on the boiler. Furthermore, igni-
tion and combustion noise may occur in the
boiler.
> Only use the gas type specified in the
type overview (
¬section1.5).
5.2 Connecting the gas line
5.1 Gas connection
> Fit an approved gas valve to the unit with a screw
connector.
> Fit the gas supply line to the gas valve.
> Purge the gas line before you start up the unit.
> Check the gas connection for leak-tightness.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ECOTEC PLUS VU 80 and is the answer not in the manual?

Vaillant ECOTEC PLUS VU 80 Specifications

General IconGeneral
BrandVaillant
ModelECOTEC PLUS VU 80
CategoryBoiler
LanguageEnglish

Related product manuals