USER'S GUIDE____________________________________________________________________
64 __________________________________________________________________ M210361EN-E
The response is the following:
a+x<CR><LF>
where
a = The sensor address.
x = The currently active submode. The options
are:
0 = submode A
1 = submode B
<CR><LF> = Terminates the response.
Place Sensor in Submode B (aXQx;c.c;n;yyyy!)
This command sets the sensor into submode B which enables calculation
of averaged wind data and gust wind speed and direction.
The command is the following:
aXQx;c.c;n;yyyy!
where
a = The sensor address.
XQ = The place sensor in submode B command.
x = The desired wind averaging method. The
options are:
0 = use scalar averaging
1 = use vector averaging
c.c = The wind direction coasting threshold in
the current wind speed units. The coasting
can only be used with scalar averaging.
n = The number of samples that form the gust
wind speed and direction value (1 Hz
sampling). The valid range is 1 to 9.
yyyy = The length of averaging window [s]
! = Terminates the command.
The response is the following:
a<CR><LF>
where
a = The sensor address.
<CR><LF> = Terminates the response.