EasyManua.ls Logo

Vanderbilt VR50M-MF - Connecting the Reader to Sipass Integrated; Connecting the Reader to Sipass Integrated in OSDP Mode; Setting OSDP Address for the Reader

Vanderbilt VR50M-MF
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Connecting the reader to SiPass integrated
9.1 Connecting the reader to SiPass integrated in OSDP mode
A SiPass integrated RIM (DRI/ERI)
B Power and A, B (OSDP)
C Reader 1 (VR50M-MF Mullion reader with keypad)
D Reader 2 (VR20M-MF Mullion reader)
E
Reader 3 (VR40S-MF MIFARE Reader with keypad
and display)
The connection between a reader and a Reader Interface Module (RIM) is as follows:
RIM (DRI/ERI) VRxx-MF
12 V +
0V -
Tx/+ A
Rx/- B
SiPass integrated can support both the VR and NGCR readers on the same OSDP bus.
9.2 Setting OSDP address for the reader
You can set the reader address to 1 (default setting), 2 , or programmed with a value from 1 to 8 using the
Jumper. Place the Jumper in one of the three positions shown in the diagram below to achieve the desired
address. Additional addresses are automatically assigned by the controller from 3 to 8 following the order
in which the readers are powered up.
© Vanderbilt 2021 31