EasyManua.ls Logo

Vanderbilt VR50M-MF - Connect 2 Readers in Wiegand Mode to an SPCA210 Door Controller

Vanderbilt VR50M-MF
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cable length guide
Mode Max. Cable length Cable
Wiegand 30m.
Screened multicore (For
example; Belden 9538)
11.3 Connect 2 readers in Wiegand mode to an SPCA210 door con-
troller
You can connect 2 VR series reader in Wiegand mode directly to an SPCA210 door controller.
Reader 1 wiring
AB-+ Terminal block
SPCA210 door controller
Reader 1 block
A
D0
B
D1
-
0V
+
+12V
R Y/T G H Terminal block
SPCA210 door controller
Reader 1 block
R
VD1
Y/T
G
VA1
H
© Vanderbilt 2021 41
A-100410-d
12.02.2021
Mullion Reader VR20 VR50 Installation Manual Connecting the VR series reader to SPC

Table of Contents

Other manuals for Vanderbilt VR50M-MF