11 Connecting the VR series reader to SPC
11.1 Connect a single-reader to an SPCA210 door controller through an
SE1190 OSDP interface
Using an SE1190 OSDP interface, you can connect a single VR series reader in OSDP mode to an
SPCA210 door controller.
A B - + Terminal block SPCA210 door controller SE1190 OSDP interface
A A
B B
- 0V
+
12V
DP51
TA
Reader jumper settings
Jumper 1 ON
Jumper 2 OFF
Jumper 3 ON
Cable length guide
Mode Max. Cable Length Cable
OSDP 500m. Screened twisted pair (For example; Belden 9501)
© Vanderbilt 2021 39