Installation
- 16 - IQ SERIES OWNERS MANUAL
2.7 (7) FLOAT CHARGE Indicator Light
The light is present on all models but is functional only on IQC Models.
(See ‘Battery Charger Theory of Operation’ for charger performance details.)
IQC Models
Light Action Description
Solid Green The unit is in Charger Mode (shore power is ON) and the charger is in the FLOAT
STAGE of the battery charging cycle.
Blinking Green Both the Battery Charger and Inverter functions have been turned OFF by turning
Program Switches 5 and 4 to the left position. Shore power is ON. (See PROGRAM
SWITCH description.)
2.8 (8) AC CIRCUIT BREAKER
IQ 20 amp Protects output circuit AC1
IQC 30 amp Protects input circuit AC1
2.9 (9) AC CIRCUIT BREAKER
IQ 15 amp Protects output circuit AC2 and GFCI
IQC 15 amp Protects GFCI
2.10 (10) AC CIRCUIT BREAKER
IQ/IQC 30 amp Protects output circuit AC3
2.11 (11) AC OUTPUT RECEPTACLE
GFCI convenience receptacle, 120vac 1800 watt maximum output, protected by 15 amp circuit breaker
CB2. The GFCI is a 15 amp receptacle and is protected by a 15 amp breaker.
** Note: If GFCI trips and the inverter is in Load Demand mode the GFCI may not reset until you toggle
inverter off and back on then you will have 5 seconds to reset GFCI before unit goes back into Load
Demand mode again or you can disable Load Demand mode via dipswitch, if available.
2.12 (12) FRONT COVER
BE SURE THE INVERTER IS TURNED OFF AND ALL EXTERNAL SOURCES OF POWER ARE
TURNED OFF BEFORE REMOVING THE FRONT COVER. The Front Cover must be removed to access
the program switches and remote control connections located on the control circuit board.