Installation
IQ SERIES OWNERS MANUAL - 25 -
3. Plug the interface cable into the inverter's wiring panel (RJ-11 telephone-type jack labeled J9 on
the control printed circuit board). Plug the other end of the cable into the rear of the remote
panel.
4. Mount the remote panel using four #8 screws.
3.7 Remote Automatic Power Management (APM) Panel Installation
Unpacking the Remote Automatic Power Management (APM) Panel
Inspect the shipping container and equipment for loose or damaged parts. If any damage is
found, immediately notify the freight carrier.
Steps
1. Locate a suitable place to install the APM panel such as a flat surface near the power
control/distribution panel, shore power switch, or driver’s compartment. The mounting surface
should have sufficient space to accommodate the remote panel's depth and cable routing. Cut
surface material large enough to accommodate the remote control box leaving sufficient surface
material to attach panel with # 8 mounting screws.
2. Route the 20ft. interface cable from the remote panel mounting area to the inverter.
3. Plug the interface cable into the inverter's wiring panel (RJ-11 telephone-type jack labeled J8 on
the control printed circuit board).
4. Plug the other end of the cable into the rear of the APM panel.
5. Mount the remote panel using four # 8 screws.