Standard Features
IQ SERIES OWNERS MANUAL - 7 -
1.3 Standard Features
1.3.1 IQ Series Standard Features
1. True RMS regulated 120 volt AC 60 Hz Quasi-sine wave output
2. Output Short circuit / overload protection through electronic sensing
3. Output circuit breakers
4. Automatic shutoff for Low Battery
5. Automatic shutoff for Overload
6. Automatic momentary shutoff/restart for Over Temperature
7. All controls accessible from the front
8. AC input/output hardwire box
9. Load Demand including Automatic Throttle Control (1 amp ground signal)
10. Load Demand Enable/Disable Switch
11. Built-in GFCI * duplex receptacle protected by a 15 amp circuit breaker.
12. Optional Remote Operating Panel and Remote ON/OFF Switch (capable of single wire control)
1.3.2 Additional Features on inverter models (example: IQ12-2600)
1. Three output circuits with 15 amp, 20 amp and 30 amp output circuit breakers
1.3.3 Additional Features on “inverter/charger” models (example: IQC12-2600)
1. Three Stage Battery Charger
2. Manually initiated Equalize Charging Cycle
3. Adjustable charge rate
4. Settings for charging wet or gel batteries
5. No minimum battery voltage required for charging (will charge a dead battery)
6. Jack for optional Battery Temperature Compensation Sensor (not available as of this printing)
7. Automatic Power Management (charger power control to prevent overloading the AC source)
8. Optional Automatic Power Management Panel
9. Automatic Transfer Switch with 5 second acceptance time delay
10. Accepts one or two 30 amp AC input circuit
11. Inverter Disable Switch to allow passthrough and battery charging only
12. Charger Disable Switch to allow passthrough only
13. Passthrough capability while battery is disconnected
14. Low AC input voltage tolerance selectable between 90VAC and 77VAC
15. Selectable Ambulance Mode to prevent automatic inverter startup upon loss of AC input power
Please note: The Battery Charger, Automatic Transfer Switch and Automatic Power Management are
operational only when AC input power (shore power) is present.
** Note: If GFCI trips and the inverter is in Load Demand mode the GFCI may not reset until you toggle
inverter off and back on then you will have 5 seconds to reset GFCI before unit goes back into Load
Demand mode again or you can disable Load Demand mode via dipswitch, if available.