INSTALLATION Series
58/119
Edition 2017-11-24 742280ED
Inquiry function
Command Acknowledgement
Description
SENSOR 2 OFFSET
Get
i:61 i:61aaaaaaaa
data length: 8 characters
aaaaaaaa sensor 2 offset (-140000 ... 0140000 = -1.4V ... +1.4V)
This function returns the sensor 2 offset voltage (adjusted by ZERO).
SENSOR 1 READING
Get
i:64 i:64saaaaaaa
data length 8 characters
s sign, 0 for positive readings, - for negative readings
aaaaaaa sensor 1 reading, return value depends on configuration,
refer to «RS232 setup commands, COMMUNICATION RANGE»
for details
This function returns direct reading from sensor 1 input.
SENSOR 2 READING
Get
i:65 i:65saaaaaaa
data length 8 characters
s sign, 0 for positive readings, - for negative readings
aaaaaaa sensor 2 reading, return value depends on configuration,
refer to «RS232 setup commands, COMMUNICATION RANGE»
for details
This function returns direct reading from sensor 2 input.