Series 670 MAINTENANCE
943070EA Edition 2018-06-19 23/
39
Description
Required tool
19. Insert the fixation disc until stop.
20. Fasten the plate screws with 5 Nm.
Allen torque
wrench
4 mm
21. Fasten the plate screws with 8 Nm.
Allen torque
wrench
5 mm
22. Switch ON the power supply.
23. Select [LOCAL].
CPA
If PFO available on IC2
controller, proceed with step
24, if not go to step 25.
24. Enable the PFO in menu: Valve >
Parameters > Power Fail Option >
Enable = [TRUE], press save
button or [Enter] on keyboard