Series 670 MAINTENANCE
943070EA Edition 2018-06-19 29/
39
Description
Required tool
15. If the valve does not start the
homing procedure automatically
(depends on valve setting), initiate
homing procedure manually: Valve
> Parameters > System > Control
Mode = [Homing], press save
button or [Enter] on keyboard.
16. Wait until Homing is finished. The
position of valve is now 20% open.
The SFV Axis Initialization
Mode will be automatically
disabled after the homing!
CPA
17. Switch OFF the power supply.
18. Install the plate, refer to chapter:
«7.2.1 Removing the plate and
plate seal replacement. Do the
steps 17 to 22.
19. Select [CLOSE], the valve is
executing Homing and moves to
close position.
CPA
20. Close the service cover. Refer to
manual of customized process
chamber.
21. Valve is ready for use.