Operating & Mounting instructions – 8 074 143.03/03 – Page 8
Analog inputs Factory See
Parameter name Adjusting range default page
A011 External frequency start O (0...10V) 0,00...400,0 Hz 0,00 Hz 19
A101 External frequency start OI (4...20mA) 0,00...400,0 Hz 0,00 Hz 19
A111 External frequency start O2 (-10...+10V) -400,0...+400,0 Hz 0,00 Hz 19
A012 External frequency end O (0...10V) 0,00...400,0 Hz 0,00 Hz 19
A102 External frequency end OI (4...20mA) 0,00...400,0 Hz 0,00 Hz 19
A112 External frequency end O2 (-10...+10V) -400,0...400,0 Hz 0,00 Hz 19
A013 Analog signal ref. for Start O (0...10V) 0...100 % 0 % 19
A103 Analog signal ref. for Start OI (4...20mA) 0...100 % 0 % 19
A113 Analog signal ref. for Start O2 (-10...+10V) -100...+100 % -100 % 19
A014 Analog signal reference for end O (0...10V) 0...100 % 100 % 20
A104 Analog signal ref. for end OI (4...20mA) 0...100 % 100 % 20
A114 Analog signal ref. for end O2 (-10...+10V) -100...+100 % 100 % 20
A015 External frequency start pattern O (0...10V) 00 or 01 01 20
A105 Ext. frequency start pattern OI (4...20mA) 00 or 01 01 20
A005 AT Terminal selection 00 or 01 01 21
A006 O2 Control selection 00 to 02 00 21
A016 Time constant for analog signals 1...30 30 21
C081
Adjustment 0...10 V input 0...9999 Default 22
C082
Adjustment 4...20 mA input 0...9999 Default 22
C083
Adjustment -10...+10 V input 0...9999 Default 22
C121
Offset-adjustment 0...10 V input 0...9999 Default 22
C122
Offset-adjustment 4...20 mA input 0...9999 Default 22
C123
Offset-adjustment -10...+10 V input 0...9999 Default 22
Multispeeds Factory See
Parameter name Adjusting range default page
A019 Multi speed selection 00 or 01 00 22
A021 Multi speed 1 0,00...400,0 Hz 0,00 Hz 22
A022 Multi speed 2 0,00...400,0 Hz 0,00 Hz 22
A023 Multi speed 3 0,00...400,0 Hz 0,00 Hz 22
A024 Multi speed 4 0,00...400,0 Hz 0,00 Hz 22
A025 Multi speed 5 0,00...400,0 Hz 0,00 Hz 22
A026 Multi speed 6 0,00...400,0 Hz 0,00 Hz 22
A027 Multi speed 7 0,00...400,0 Hz 0,00 Hz 22
A028 Multi speed 8 0,00...400,0 Hz 0,00 Hz 22
A029 Multi speed 9 0,00...400,0 Hz 0,00 Hz 22
A030 Multi speed 10 0,00...400,0 Hz 0,00 Hz 22
A031 Multi speed 11 0,00...400,0 Hz 0,00 Hz 22
A032 Multi speed 12 0,00...400,0 Hz 0,00 Hz 22
A033 Multi speed 13 0,00...400,0 Hz 0,00 Hz 22
A034 Multi speed 14 0,00...400,0 Hz 0,00 Hz 22
A035 Multi speed 15 0,00...400,0 Hz 0,00 Hz 22
A038 Jogging frequency 0,00...9,99 Hz 1,00 Hz 23
A039 Stop mode of jog function 00 to 05 00 23