EasyManua.ls Logo

Vega MINITRAC 31 - 10 Dismount; 10.1 Dismounting steps; 10.2 Disposal

Vega MINITRAC 31
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
11 Supplement
MINITRAC 31 • 4 … 20 mA/HART - four-wire
40447-EN-130430
Signal resolution 0.3 µA
Failure signal current output (adjustable) 22 mA, < 3.6 mA
Max. output current 22 mA
Starting current ≤3.6mA
Load
Ʋ 4 … 20 mA/HART - active <500Ω
Ʋ 4 … 20 mA/HART - intrinsically safe <300Ω
Damping (63 % of the input variable) 1 … 1200 s, adjustable
HART output values
Ʋ PV(PrimaryValue) Level
Ʋ SV(SecondaryValue) Electronics temperature
Output variable - Density measurement
Output signals 4 … 20 mA - aktiv; 4 … 20 mA/HART - passiv
Terminal voltage passive 9…30VDC
Shortcircuit protection Available
Potential separation Available
Signal resolution
0.3 µA
Failure signal current output (adjustable) 22 mA, < 3.6 mA
Max. output current 22 mA
Starting current ≤3.6mA
Load
Ʋ 4 … 20 mA/HART - active <500Ω
Ʋ 4 … 20 mA/HART - intrinsically safe <300Ω
Damping (63 % of the input variable) Automatically
HART output values
Ʋ PV(PrimaryValue) Density value
Ʋ SV(SecondaryValue) Electronics temperature
Output variable - Level detection
Output signals 8/16 mA
Terminal voltage passive 9…30VDC
Shortcircuit protection Available
Potential separation Available
Failure signal current output (adjustable)
22 mA, < 3.6 mA
Max. output current 22 mA
Starting current ≤3.6mA
Load
Ʋ 4 … 20 mA/HART - active <500Ω
Ʋ 4 … 20 mA/HART - intrinsically safe <300Ω
Damping (63 % of the input variable) Automatically
HART output values

Other manuals for Vega MINITRAC 31

Related product manuals