NOTE: The integrated control must be turned OFF to use this control.
ADJUSTING AIR SUPPLY CONTROL
1) Select “RE-CIRC”, “MIN.” or “AUTO” using the push button.
• When “RE-CIRC” is selected, the recirculation indicator lights up. If the humidity control
knob is set to the left of the “click”, the unit will recirculate air on high speed and if it is
set to the right of the “click”, the unit will exchange air, on high speed, with the outside
until the desired humidity level has been reached. During this time, the excess humidity
and air exchange indicators will be lit.
• When “MIN.” is selected, the minimum speed and air exchange indicators light-up. If the
humidity control knob is set to the left of the “click”, the unit will exchange in low speed
with the outside and if it is set to the right of the “click”, the unit will exchange air, on
high speed, with the outside until the desired humidity level has been reached. During
this time, the excess humidity indicator will be lit.
• When “AUTO” is selected, the automatic indicator lights-up. If the humidity control knob
is set to the left of the “click”, the unit will turn OFF for the first 40 minutes and operate
on air exchange mode with the outside, in low speed, during the last 20 minutes of the
hour. The air exchange indicator will be lit. If the humidity control knob is set to the right
of the “click”, the unit will exchange air, on high speed, with the outside until the desired
humidity level has been reached. During this time, the excess humidity indicator will be lit.
2) To turn off the unit, press on the push button once again.
ADJUSTING HUMIDITY CONTROL
SETTING DURING THE SUMMER MONTHS:
During this period, unless being afflicted with breathing problems, using the humidity control
is unnecessary; set the unit in recirculation mode. (Do not exchange in day time; exchange
at night time if cool outside or if it’s not raining.)
SETTING DURING THE FALL, WINTER AND SPRING MONTHS (CONDENSATION APPEARS ON WINDOWS):
1) Determine the humidity level in your house (bring the knob counterclockwise to its
maximum position, then bring it back clockwise slowly until you hear a “click”).
2) Set the knob to one line under this temperature level or “click”.
6.1 BREEZE MAIN CONTROL (PRO250 ONLY)
CAUTION
Do not set a temperature below -20°C (-4°F). This could lead to excessive
dryness in the air causing discomfort for the occupants.
It is possible (and normal) to experience condensation on your windows when drastic
changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case,
we suggest waiting a few days to allow the situation to stabilize.
HUMIDITY
CONTROL KNOB
EXCESS HUMIDITY
INDICATOR
AIR EXCHANGE
INDICATOR