If you think your unit is malfunctioning, check some of the followings:
8. TROUBLESHOOTING
1.
PROBLEMS TRY THIS...
The LED of the
integrated control is
blinking red.
There is a problem with the exhaust motor. The unit is
OFF. Contact your installer.
2. The LED of the
integrated control is
blinking green.
There is a problem with the thermistor. The unit is still
working, but will defrost frequently. Contact your installer.
3. The LED of the
integrated control
is blinking amber.
There is a problem with the motorized damper. The unit is
OFF. For a 2½-hour period, the unit will try to reset the
damper at every 30 minutes. After 2½ hours, if the
problem is not solved, the unit stops trying to reset
damper.
Contact your installer.
Check control wir ing.
4. The integrated control
push button does not
work.
The 30-second boot sequence is not completed. See
Booting Sequence on page 14.
5. Nothing works. See if the unit is plugged in.
See if the unit is receiving power from the house circuit
breaker or fuse.
6. Condensation
on windows.
(Air too humid.)
Adjust the humidity control knob as per instructions (see
Section 6).
Leave curtains half-open to allow air circulation.
Store all firewood in a close room with a dehumidifier or
in a well ventilated room, or store the wood outside.
•Keep the temperature in your house above 18°C (64°F).
Set the unit at high speed during activities generating
excess humidity (family gatherings, extra cooking, etc.).
7. Air too dry. Temporarily use a humidifier.
Using integrated control, set the unit at low speed.
PRO250 unit only (with Breeze control)
- Do not adjust your humidity control below -20°C (-4°F).
- Set the unit at minimum speed (MIN.).
- Temporarily switch to the AUTOMATIC mode.
PRO225 unit only (with 11136 control)
- Set the Humidity level selector below 30% (see 6.2 on
page 18).
8. Air too cold at the air
supply grille.
•Make sure the outside ports are not blocked.
•Have the unit defrost system checked.
•Install a duct heater.
Using integrated control, set the unit at low speed.
PRO250 unit only (with Breeze control)
- Set the unit at minimum speed (MIN.).