4. UNIT INSTALLATION (CONT’D)
4.2 LOCATING AND MOUNTING THE UNIT
Choose an appropriate location for the unit:
Within a heated area of the house (10 °C/50 °F or more)
Away from living areas (dining room, living room, bedrooms), if possible
So as to provide easy access for filter maintenance
Close to an exterior wall, so as to limit the length of the insulated flexible ducts to
and from the unit
Close to a drain. (If no drain is close by, use a pail to collect run-off)
Away from hot chimneys, electrical panel and other fire hazards
Allow for a power source (standard 3-prong grounding outlet)
Use the 4 chains and springs (from the hardware pack included with the unit) to hang the
unit to ceiling joists.
Robertson no. 2 or
Phillips no. 2 screwdriver
Cutter pliers
Drill
Jig saw
Duct tape
Caulking gun with a tube of silicone
sealant
•Metal shears (if the exterior covering is
aluminum or vinyl)
Chisel and hammer (if the exterior covering
is brick)
4.3 TOOLS AND MATERIALS
4.4 HOW TO HANG THE UNIT
CAUTION
Make sure the unit is level.
VD0204