SENSOR CONFIGURATION
B001167
CALIBRATE THE SENSORS
Fuel level sensor
Connect the sensor of interest. See Connecting an analogue sensor.
Under
Sensors
select the resistive input to which the sensor is connected.
Under
Fuel
>
Sensor,
choose the desired configuration type.
If you have chosen the
CUSTOM
configuration, follow the wizard on the display to create the sensor
curve.
Under
Sensors
select the resistive input of step 2.
Under
Fuel
>
Tank no.,
select the ID to be assigned to the tank to which the sensor is connected.
Fresh water level sensor
Connect the sensor of interest. See Connecting an analogue sensor.
Under Sensors select the resistive input to which the sensor is connected.
In Fresh water > Sensor choose the desired configuration type.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
Under Sensors select the resistive input of step 2.
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
WASTEWATER LEVEL SENSOR
Connect the sensor of interest. See Connecting an analogue sensor.
Under Sensors select the resistive input to which the sensor is connected.
In Wastewater > Sensor choose the desired configuration type.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
Under Sensors select the resistive input of step 2.
Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
RUDDER ANGLE SENSOR
Connect the sensor of interest. See Connecting an analogue sensor.
Under Sensors select the resistive input to which the sensor is connected.
In Rudder choose the desired configuration type.
If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
TRIM SENSOR
Connect the sensor of interest. See Connecting an analogue sensor.
Under Sensors select the resistive input to which the sensor is connected.
In Trim follow the wizard on the display to create the sensor curve.
RPM SENSOR
Connect the sensor of interest. See Connecting an analogue sensor.
In Sensors > RPM > Config enter the value of pulses/revolution required for a correct reading of the
signal.