SENSOR CONFIGURATION
B001167
CALIBRATE THE SENSORS
Fuel level sensor
• Connect the sensor of interest. See Connecting an analogue sensor.
• Under
Sensors
select the resistive input to which the sensor is connected.
• Under
Fuel
>
Sensor,
choose the desired configuration type.
• If you have chosen the
CUSTOM
configuration, follow the wizard on the display to create the sensor
curve.
• Under
Sensors
select the resistive input of step 2.
• Under
Fuel
>
Tank no.,
select the ID to be assigned to the tank to which the sensor is connected.
Fresh water level sensor
• Connect the sensor of interest. See Connecting an analogue sensor.
• Under Sensors select the resistive input to which the sensor is connected.
• In Fresh water > Sensor choose the desired configuration type.
• If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
• Under Sensors select the resistive input of step 2.
• Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
WASTEWATER LEVEL SENSOR
• Connect the sensor of interest. See Connecting an analogue sensor.
• Under Sensors select the resistive input to which the sensor is connected.
• In Wastewater > Sensor choose the desired configuration type.
• If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
• Under Sensors select the resistive input of step 2.
• Under Fresh water > Tank no., select the ID to be assigned to the tank to which the sensor is connected.
RUDDER ANGLE SENSOR
• Connect the sensor of interest. See Connecting an analogue sensor.
• Under Sensors select the resistive input to which the sensor is connected.
• In Rudder choose the desired configuration type.
• If you have chosen the CUSTOM configuration, follow the wizard on the display to create the sensor
curve.
TRIM SENSOR
• Connect the sensor of interest. See Connecting an analogue sensor.
• Under Sensors select the resistive input to which the sensor is connected.
• In Trim follow the wizard on the display to create the sensor curve.
RPM SENSOR
• Connect the sensor of interest. See Connecting an analogue sensor.
• In Sensors > RPM > Config enter the value of pulses/revolution required for a correct reading of the
signal.