Table A-3
Veritas Appliance compute node environmental specifications
(continued)
5340 Appliance compute nodeSpecification
8% RH to 90% RHNon-operating
humidity
-30 to 3000 m with ASHRAE A2 class derating (0 to 10,000 ft)Operating altitude
(feet)
10°C/h (50°F/h)Temperature gradient
(per hour)
Veritas 5U84 Primary Storage Shelf / 5U84 Expansion
Storage Shelf environmental specifications
Table A-4
Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage
Shelf environmental specifications
DescriptionSpecification
Operating: to 35ºC (de-rate 5ºC above 2,133m (7,000’)) (41°F
to 95°F)
Non-operating: -40°C to 70°C (-40°F to 158°f)
Temperature range
Operating: 20%rh to 80%rh non-condensing
Non-operating: 5%rh to 100%rh non-condensing
Relative humidity
-30 to 3048m ( -100 to 10000ft)
De-rate 5°C above 2134m (7000ft)
Operating altitude
-305 to 12192m ( -1000 to 40000ft)Non-operating altitude
Operating: 28°C
Non-operating: 29°C
Maximum wet bulb
See 5340 Appliance compute node technical specifications” on page 76.
See Veritas 5U84 Storage Shelf technical specifications” on page 79.
See “Protocol standards” on page 83.
See “Regulatory, compliance, and certification information” on page 83.
82Technical specifications, Environmental/Protocol standards, and Compliance standards
Environmental specifications

Table of Contents

Other manuals for VERITAS NetBackup 5340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the VERITAS NetBackup 5340 and is the answer not in the manual?

VERITAS NetBackup 5340 Specifications

General IconGeneral
BrandVERITAS
ModelNetBackup 5340
CategoryServer
LanguageEnglish

Related product manuals