Table A-2
Veritas 5U84 Primary Storage Shelf / 5U84 Expansion Storage
Shelf technical specifications (continued)
DescriptionTechnical specification
0.21gRMS 5-500Hz RandomOperational vibration
5g10ms ½ SineOperational shock
0.3g2-200-2Hz Swept Sine.Relocation vibration
(Non-operational)
1.04 gRMS 2-200Hz Random.Non-operational vibration
30g10ms ½ Sine (Z-axis)
20g10ms ½ Sine(X-and Y-axes)
Non-operational shock
See “ 5340 Appliance compute node technical specifications” on page 76.
See “Environmental specifications” on page 81.
See “Protocol standards” on page 83.
See “Regulatory, compliance, and certification information” on page 83.
Environmental specifications
Veritas Appliance compute node environmental
specifications
Table A-3
Veritas Appliance compute node environmental specifications
5340 Appliance compute nodeSpecification
ASHRAE A2 (10°C to 35°C ) (50°F to 95°F)Operating temperature
-25°C to 70°C (-14°F to 158°F)
The non-operating temperature is defined as the temperature of the
system when the system is turned off. It is also referred to as the
storage temperature.
Veritas recommends that you do not store the system in an
environment where the temperatures fall outside of the listed
temperature range.
Non-operating
temperature
20% RH to 80% RHOperating humidity
(RH)
81Technical specifications, Environmental/Protocol standards, and Compliance standards
Environmental specifications