Page 41
RAKE-WALL - FIND STUD LENGTHS &
ANGLE OF INCLINE
Example: A rake-wall features a base height
of 7 Feet, a peak (rise) of 5 Feet, and a length
(run) of 10 Feet.
Determine the stud lengths and calculate the
angle of incline for the rake-wall.
For this example, assume you are not using
the standard On-center spacing of 16 Inches,
but instead are using 14 Inches.
KEY INPUT & DISPLAY
0
2. Enter the rise and run of the section above the base of the rake-wall:
RISE 5
Feet
0
Inch
RUN 10
Feet
0
Inch
BASE 7
Feet
0
Inch
RWOC 14
Inch
3. Enter the height of the base, then nd stud lengths and angle of incline:
RW1 11
Feet
5
Inch
RW 26.57˚
RW2 10
Feet
10
Inch
RW3 10
Feet
3
Inch
RW4 9
Feet
8
Inch
RW5 9
Feet
1
Inch
BASE 7
Feet
0
Inch
STORED
RW6 8
Feet
6
Inch
Rise
RW7 7
Feet
11
Inch
Rise
OC 14
Inch
*
STORED
*Remember to reset back to standard 16 Inches later. .
1. Set the On-center spacing to 14 Inches:
RW8 7
Feet
4
Inch
Rise
RAKE-WALLS
Remember to press to clear entries in between problems.
On/C On/C
On/C On/C
Rise
Run
Feet
5
1
0
Feet
Rise
Rise
Rise
Rise
Rise
Rise
Rise
Rise
Rise
Feet
Conv
7
(R/Wall)
Inch
Stor
5
1
4
10’
5’
7’